For overseas buyers targeting North America’s $54 billion light box market, the UL certification of double-sided circular light boxes is no longer just a "market access pass"—it has become a core competitive advantage in commercial scenarios such as retail storefronts, gas stations, and urban advertising. In 2024, UL (Underwriters Laboratories) launched key updates to standards including UL 48 (Electric Signs) and UL 1598 (Lighting Equipment), which directly affect the compliance of circular light boxes in North American commercial applications. This article deciphers the updated requirements and provides practical compliance guidance for global buyers.
UL certification is recognized by U.S. federal regulations and Canadian provincial standards, covering electrical safety, mechanical stability, and environmental adaptability—three pain points for commercial light box applications. For double-sided circular light boxes, which feature a curved structure, dual-sided lighting design, and frequent outdoor use, UL certification solves three core concerns of North American buyers:
A 2025 survey by the American Signage Foundation shows that 82% of commercial light box procurement projects in North America list UL certification as a mandatory requirement, an increase of 15 percentage points from 2023.
The 2024 revisions to UL 48 and UL 1598 (Rev. January 31, 2024) have added targeted requirements for double-sided circular light boxes, focusing on three key areas:
The updated UL 48 standard emphasizes two mandatory requirements for LED double-sided light boxes:
For example, a 120V commercial circular light box must now pass a 1500V withstand voltage test for its secondary circuit, with no breakdown allowed for 1 minute.
Aiming at the curved structure of circular light boxes, the updated standard has refined mechanical safety and material flame retardancy requirements:
The updated standard has standardized the labeling requirements for double-sided circular light boxes, which must include:
Buyers should note that missing any of the above labels may result in refusal of market access during retailer audits.
Different commercial application scenarios correspond to differentiated UL testing requirements. Kingwe-star summarizes three common scenarios and their core standards:
|
Commercial Scenario
|
Core UL Standard
|
Key Test Items
|
Special Requirements
|
|---|---|---|---|
|
Gas Station Advertising (Hazardous Area)
|
UL 48 + UL 844
|
Explosion-proof test, leakage current test
|
IP66 protection level, anti-static shell
|
|
Mall Entrance (Indoor Wet Area)
|
UL 1598 (2024 Rev.)
|
Humidity cycle test, corrosion resistance
|
Resistant to cleaning agent erosion (simulated daily cleaning)
|
|
Outdoor Street Sign (Cold Region)
|
UL 48 + UL 8800
|
Low-temperature cycle test (-40℃ to +50℃)
|
No structural deformation after 100 temperature cycles
|
A Toronto-based advertising company planned to import 300 double-sided circular light boxes for a fast-food chain’s outdoor promotion in early 2024. Initially, the supplier provided products certified to the old UL 48 standard, which lacked secondary circuit grounding and new labeling. During the pre-shipment inspection, Kingwe-star’s compliance team identified the issue and proposed two solutions:
After the rectification, the products passed Canadian customs clearance smoothly, and the fast-food chain’s promotion was launched on schedule. The buyer’s procurement manager stated: "The updated UL certification not only avoids fines but also makes our products more competitive in the local bidding."
Based on serving 87+ North American light box buyers, Kingwe-star summarizes a three-step compliance method:
To help overseas buyers quickly adapt to the 2024 UL certification updates, Kingwe-star provides free one-stop services: including UL standard interpretation, component selection guidance, and third-party test report review. Our team of engineers with 10+ years of experience in lighting certification can simulate North American commercial scenarios to conduct targeted pre-testing, ensuring that each batch of double-sided circular light boxes meets market requirements.
For a personalized UL certification compliance checklist for your commercial light box project, please contact Kingwe-star or visit Kingwe-star to submit your needs.
For overseas buyers targeting North America’s $54 billion light box market, the UL certification of double-sided circular light boxes is no longer just a "market access pass"—it has become a core competitive advantage in commercial scenarios such as retail storefronts, gas stations, and urban advertising. In 2024, UL (Underwriters Laboratories) launched key updates to standards including UL 48 (Electric Signs) and UL 1598 (Lighting Equipment), which directly affect the compliance of circular light boxes in North American commercial applications. This article deciphers the updated requirements and provides practical compliance guidance for global buyers.
UL certification is recognized by U.S. federal regulations and Canadian provincial standards, covering electrical safety, mechanical stability, and environmental adaptability—three pain points for commercial light box applications. For double-sided circular light boxes, which feature a curved structure, dual-sided lighting design, and frequent outdoor use, UL certification solves three core concerns of North American buyers:
A 2025 survey by the American Signage Foundation shows that 82% of commercial light box procurement projects in North America list UL certification as a mandatory requirement, an increase of 15 percentage points from 2023.
The 2024 revisions to UL 48 and UL 1598 (Rev. January 31, 2024) have added targeted requirements for double-sided circular light boxes, focusing on three key areas:
The updated UL 48 standard emphasizes two mandatory requirements for LED double-sided light boxes:
For example, a 120V commercial circular light box must now pass a 1500V withstand voltage test for its secondary circuit, with no breakdown allowed for 1 minute.
Aiming at the curved structure of circular light boxes, the updated standard has refined mechanical safety and material flame retardancy requirements:
The updated standard has standardized the labeling requirements for double-sided circular light boxes, which must include:
Buyers should note that missing any of the above labels may result in refusal of market access during retailer audits.
Different commercial application scenarios correspond to differentiated UL testing requirements. Kingwe-star summarizes three common scenarios and their core standards:
|
Commercial Scenario
|
Core UL Standard
|
Key Test Items
|
Special Requirements
|
|---|---|---|---|
|
Gas Station Advertising (Hazardous Area)
|
UL 48 + UL 844
|
Explosion-proof test, leakage current test
|
IP66 protection level, anti-static shell
|
|
Mall Entrance (Indoor Wet Area)
|
UL 1598 (2024 Rev.)
|
Humidity cycle test, corrosion resistance
|
Resistant to cleaning agent erosion (simulated daily cleaning)
|
|
Outdoor Street Sign (Cold Region)
|
UL 48 + UL 8800
|
Low-temperature cycle test (-40℃ to +50℃)
|
No structural deformation after 100 temperature cycles
|
A Toronto-based advertising company planned to import 300 double-sided circular light boxes for a fast-food chain’s outdoor promotion in early 2024. Initially, the supplier provided products certified to the old UL 48 standard, which lacked secondary circuit grounding and new labeling. During the pre-shipment inspection, Kingwe-star’s compliance team identified the issue and proposed two solutions:
After the rectification, the products passed Canadian customs clearance smoothly, and the fast-food chain’s promotion was launched on schedule. The buyer’s procurement manager stated: "The updated UL certification not only avoids fines but also makes our products more competitive in the local bidding."
Based on serving 87+ North American light box buyers, Kingwe-star summarizes a three-step compliance method:
To help overseas buyers quickly adapt to the 2024 UL certification updates, Kingwe-star provides free one-stop services: including UL standard interpretation, component selection guidance, and third-party test report review. Our team of engineers with 10+ years of experience in lighting certification can simulate North American commercial scenarios to conduct targeted pre-testing, ensuring that each batch of double-sided circular light boxes meets market requirements.
For a personalized UL certification compliance checklist for your commercial light box project, please contact Kingwe-star or visit Kingwe-star to submit your needs.